STUDENTS! In this case, PDF #1 above contains the experimental procedure to be used in class, while PDF #2 is the pre-lab assignment.
Name | Location | Quantity |
Coil, Inductor (Heath/Coilcraft) | JE-105A-S53 | 1 per table |
Multimeter, Digital, Extech EX420 - Battery | JE-105A-D103 | 1 per table |
Power Supply, Extech (Model #382213) | JE-105A-X12/13 | 1 per table |
Wires, Banana, Black, 55cm | In Front of JE105, JE107, JE109 | 2 per table |
Wires, Banana, Red, 55cm | In Front of JE105, JE107, JE109 | 2 per table |
Magnet, 2.5x2cm, w/ hole | JE 105A-S75 | 1 per table |
Compass, Directional, Magnetic | JE-105A-S46 | 1 per table |
Wire, Taped to graph paper | JE105A-S46 | 1 per table |
Holder, D-Battery, Single | JE-105A-s136 | 1 per table |
Galvanometer | JE-105A-S51 | 1 per room |
Labpros | JE-105A-S161 | 1 per table |
Adapter, USB to LabPro | JE-105A-S161 | 1 per table |
Adapters, Labpro Power | JE-105A-S161 | 1 per table |
Battery, D 1.5V | JE-105A-S136,D100 | 1 per table |
Sensors, Magnetic Field | JE-105A-S155 | 1 per table |
Magnet, Ceramic, Dowling, 4.7x2.2cm | JE-105A-S75 | 1 per room |
Magnet, Steel, Bar, 15x1.9cm | JE-105A-S75 | 1 per room |
Switch, Momentary, Contact Key, Telegraph | JE-105A-S137 | 1 per table |
Place magnets on the tables away from the compasses and other sensitive equipment. Use the plastic ones for this set up Use the wire attached to the graph paper in the circuit. Leave the bolts on the tables instead of screwed into the light bulb holders. This ensures the circuit is open. Plug in the inductor coil to the power supply. Use the momentary switch.